TM9V
Nominal Capacities
40 - 120 MBH Input

Efficiency
96% AFUE

Warranty
Compressor - NA
Heat Exchanger - Lifetime
Parts - 10-Year Limited*

96% 2 Stage VS ECM Multi-Position Gas Furnace

These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications.


These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation.


These units are Category IV listed and may be vented either through side wall or roof applications using approved plastic combustion air and venr piping.



Special Benefits
  • Compact, easy to install, ideal height 33" tall cabinet.
  • Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary.  
  • Two stage heating operation includes two stage gas valve, two stage inducer operation and variable speed ECM blower operation. Adjustable delay timer allows two stage operation with a single stage thermostat.
  • ECM variable speed drive for cooling SEER enhancement, improved comfort with optional airflow delay profiles, and continuous fan options for IAQ performance.
  • Easy access to controls to connect power/control wiring.
  • Built-in, high level self diagnostics with fault code display.
  • Low unit amp requirement for easy replacement application.
  • All models are convertable to use propane (LP) gas.
  • Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.
  • 100% shut off main gas valve for extra safety.
  • 24V, 40 VA control transformer and blower relay supplied for add-on cooling.
  • Hi-tech tubular aluminized steel primary heat exchanger with stainless steel tube/aluminum fin secondary heat exchanger for outstanding efficiency.
  • Solid removable bottom panel allows easy conversion.
  • Airflow leakage less than 1% of nominal airflow for ductblaster conditions.
  • No knockouts to deal with, making installation easier.
  • Movable duct connector flanges for application flexibility.
  • Quiet two speed inducer operation, burner, and blower operation.
  • Inducer rotates for easy conversion of venting options.
  • Fully supported blower assembly for easy access and removal of blower.
  • External air filters used for maximum flexibility in meeting customers IAQ needs.
  • Insulated blower compartment for thermal and acoustic performance.
  • 1/4 turn knobs provided for easy independent door removal.
  • Internal condensate trap design (patent pending) provides condensate management options, easy visual operation check, and is self priming to prevent nuisance problems.
  • Protection included from air intake, exhaust vent or condensate blockage.
  • Venting applications maybe installed as either 2 pipe sealed combustion or single pipe vent using indoor combustion air.

*Must be installed on or after May 1st, 2009, and registered online within 90 days of installation. Otherwise, the warranty reverts to the standard warranty as published in the product warranty certificate.


Publications and Manuals
DescriptionPart NumberFile Size
Consumer Brochures
Consumer Brochure - LX Series Gas Furnaces (80% up to 97% AFUE) PUBL-6174-E-0713 1362 KB PDF
Tech Guides
Technical Guide - TM9V 96% AFUE 2 Stage Variable Speed Multi-Position Gas Furnaces 700707-CTG-E-0913 214 KB PDF
Installation Instructions
Installation Manual - TM9V*MP 96% AFUE Two Stage Variable Speed ECM Multi-Position Gas Furnace 1083294-UIM-A-0114 5503 KB PDF
Accessory Installation Instructions
Guide d' Installations - S1-1CT0302-636/S1-1CT0303-636 Terminaison D'Event Concentrique 435695-UAIF-A-1108 71 KB PDF
Installation Accessory - 1BR0514/614, 1BR0517/617, 1BR0521/621 & 1BR0524/624 External Bottom Mount Filter Frame Acessory 506177-UAI-A-0309 37 KB PDF
Installation Accessory - 1CT0302, 1CT0303 Concentric Vent Termination 66641-UIM-F-0905_035-14287-000 73 KB PDF
Installation Accessory - 1HT0901 Side Wall Vent Kit (1-1/2”, 2” or 3” vent systems) 276015_035-20614-001-A-0804 47 KB PDF
Installation Accessory - 1HT0902 Side Wall Vent Kit (1-1/2” or 2” vent systems) 276016-UAI-A-1006 125 KB PDF
Installation Accessory - 1NP0347 Propane Conversion - Induced Combustion Furnaces 1065603-UAI-A-1013 219 KB PDF
Installation Accessory - 1SR0200 Filter Frame 1135041-UAI-A-0414 45 KB PDF
Installation Accessory - 1SR0200, 1BR0114, 1BR0214, 1BR0117, 1BR0217, 1BR0121, 1BR0221, 1BR0124, & 1BR0224 Filter Rack Kits 171002-UAI-B-0514 49 KB PDF
Installation Accessory - 1SR0402 Filter Frame 430731-UAI-A-0908 38 KB PDF
Installation Accessory - Burner Alignment Bracket for use with All 33" Gas Furnaces 826018-UAI-A-1111 106 KB PDF
Installation Accessory - Control Board Kit (P/N S1-33103012000) for use with all Communicating Two-Stage Variable Speed Models 035-23655-001-B-0614 151 KB PDF
Installation Accessory - Ignition Control (P/N S1-33102977000) for use with all Two-Stage Variable Speed Furnaces 035-23069-001-A-1010 124 KB PDF
Installation Accessory - S1-1PS3308 (96%) and 1PS3309 (80%) High Altitude Application Conversion for Two Stage Furnaces 035-22764-001-D-0110 23 KB PDF
Installation Accessory - S1-32642583000 and S1-3264594000 Inducer Replacement Kits 035-22216-002-E-0814 98 KB PDF
Installation Accessory - S1-32924441000 SS Burner Kit 035-21367-001-B-0412 12 KB PDF
Installation Accessory - S1-33102955000 Ignition Control P/N 035-22272-001-A-0409 141 KB PDF
Installation Accessory - S1-37327813001 Furnace Label Kit 341248-UAI-A-0707 11 KB PDF
Installation Accessory - S1-37327905001 thru S1-37327905006 (2 Cell thru 7 Cell) 33" Burner Box Kits for all 33" Gas Furnaces 533818-UAI-C-0413 99 KB PDF
Submittal Drawings
Submittal Data Sheet - TM9V 96% AFUE 2 Stage Variable Speed Multi-Position Gas Furnaces 700710-USD-C-0513 95 KB PDF
Repair Parts
Repair Parts - Condensate Pan Replacement for Use with All Condensing - 95+ AFUE 33" Gas Furnaces 035-22785-002-A-0511 82 KB PDF
Repair Parts - TM9T and TM9V Series Furnace Pressure Switch Wiring Harness. 035-22781-001-A-1009 83 KB PDF
Repair Parts - TM9V Series 95% AFUE Two Stage Variable Speed Multi-Position 33" Gas Furnaces "Style A" 035-22194-001-G-1213 747 KB PDF
Repair Parts - TM9V Series 95% Two Stage Variable Speed 33" Nat Gas Furnaces (Style B) 035-23626-001-A-0313 987 KB PDF
Miscellaneous
Quick Reference Guide - 96% AFUE Two Stage Variable Speed Multi-Position 33" Gas Furnaces 1083301-URG-A-0114 258 KB PDF


Terms and Conditions | Privacy Policy
  Coleman® Coleman Logo and Coleman Logo are registered trademarks of The Coleman Company, Inc., used under license.
© 2001-2014 Johnson Controls, Inc. All rights reserved.
URL: http://colemanac.com/dealers/ProductPage.asp