

 Products 
|
 |
Nominal Capacities
24 - 60 MBH
Efficiency
13.0 SEER / 10.7 to 11.4 EER / 3.0 to 3.4 COP / 7.7 HSPF
Warranty
Compressor - 10-Year Limited* Parts - 10-Year Limited*
 |
BUZ 024 to 060 Packaged Heat Pump
UPG, B*UZ Series single-package heat pumps are designed for outdoor installation that saves indoor living space. Nominal airflow of 800 to 2,000 CFM is provided by multi-speed, direct-drive motors. To make installation and maintenance easier, they offer field convertible side or bottom airflow, removable base rails, and bottom electrical connections. All models have the same footprint, so curbs can be placed and then the proper tonnage unit can be installed after the internal load has been determined. The compact dimensions allow any model to fit between the wheel wells of a full-size pickup truck for transport. B*UZ units are also offered in three-phase configurations with 208/230 and 460 voltages.
Special Benefits
- All model sizes share a common, compact design cabinet in a single footprint for on-site flexibility.
- Installation time and costs are reduced by easy power and control wiring.
- All units are factory wired, charged with R-410a, and tested prior to shipment.
- Electric utility knockouts are provided on unit side and bottom for easy connections.
- Convertible airflow design means no panel cutting is required, and no accessory panel is necessary.
- Condensate pan is non-corrosive, long-lasting, and watertight.
- Condensate drain is heavy-duty.
- Durable finish, made of powder-painted, galvanized steel to meet 1000-hour salt-spray test demands.
- Full-perimeter base rails are easily removable, yet provide a solid unit foundation.
- Top discharge allows warm air to be blown up away from the structure and landscaping.
- Engineered and built to be among the quietest.
Compressor is internally protected against high pressure and temperature.
- Grooved copper tubes and enhanced aluminum fin construction improve heat transfer.
- Permanently lubricated condenser and evaporator fan motor bearings need no annual maintenance.
- Secured service access ports are protected, externally mounted, and re-usable on both high and low lines.
- Easy service access via a large single panel covering the electrical controls.
*Must be installed on or after May 1st, 2009, and registered online within 90 days of installation. Otherwise, the warranty reverts to the standard warranty as published in the product warranty certificate. This warranty does not apply to R-22 or 3-phase models.
|
|
|
|
| Publications and Manuals |
| Description | Part Number | File Size |
| Consumer Brochures |
| Consumer Brochure - Echelon™ Series 2 to 5 Ton Package Air Conditioners and Heat Pump Units (13 to 16 SEER) |
PUBL-6469-B-0612 |
1194 KB PDF |
| Made In the U.S.A. Coleman Light Commercial Product |
M-193-2010 |
36 KB PDF |
| Tech Guides |
| Technical Guide - BUX, BUQ and BUZ024 - 060 Echelon™ R-410A Single Package Heat Pumps (Norman Built) |
333498-CTG-H-0511 |
2840 KB PDF |
| Technical Guide - BUZ024 - 060 Echelon™ R-410A Single Package Heat Pumps (Wichita Built) |
718429-CTG-A-0811 |
1277 KB PDF |
| Submittal Drawings |
| 1AK0107 Round Adapter Kit |
530.46-SD13C-1195 |
26 KB PDF |
| 1BD0406 Burglar Bar Kit |
036-22820-002-A-1003 |
162 KB PDF |
| 1FA0406 Manual Outdoor Air Damper (0% to 50% Capability) |
530.46-SD14C-1195 |
27 KB PDF |
| 1HG0814 & 1HG0818 Hail Guard Kit for Cooling and Heat Pump Units |
530.46-SD17C-0597 |
39 KB PDF |
| 1RC0449 & 1RC0463 Roof Curb |
530.46-SD10C-0197 |
25 KB PDF |
| 2EE04703124 Economizer for Down Supply/Return Applications |
530.46-SD19Y-0797 |
226 KB PDF |
| 2FA08700124 - Motorized Fresh Air Damper (0% to 50% Capability) |
530.46-SD15C-0297 |
46 KB PDF |
| Submittal Data Sheet - BUZ024 thru 060 R-410A Echelon™ Single Package Heat Pumps (13 SEER) (Norman Built) |
277377-CSD-D-1009 |
85 KB PDF |
| Submittal Data Sheet - BUZ024 thru 060 R-410A Echelon™ Single Package Heat Pumps (13 SEER) (Wichita Built) |
277377-CSD-E-0711 |
80 KB PDF |
| CAD Drawings |
| CAD Drawing - BUZ, BHZ 024 to 036 |
MBD0188A.DWG |
KB PDF |
| CAD Drawing - BUZ, BHZ 042 to 060 |
MBD0189A.DWG |
KB PDF |
| CAD Drawing - DWG -BUX, BUZ, BHZ, BHX 042 to 060 |
AAZ0052A.DWG |
KB PDF |
| CAD Drawing - DWG -BUZ, BUX, BHZ, BHX 024 to 036 |
AAZ0051A.DWG |
KB PDF |
| CAD Drawing DXF - BUZ, BHZ 024 to 036 |
MBD0188A.DXF |
KB PDF |
| CAD Drawing DXF - BUZ, BHZ 042 to 060 |
MBD0189A.DXF |
KB PDF |
| CAD Drawing DXF - DWG -BUX, BUZ, BHZ, BHX 042 to 060 |
AAZ0052A.DXF |
KB PDF |
| CAD Drawing DXF - DWG -BUZ, BUX, BHZ, BHX 024 to 036 |
AAZ0051A.DXF |
KB PDF |
| Repair Parts |
| Repair Parts – BBUZ Series R-410a Single Packaged Heat Pumps “Style A & B” (13 SEER) |
035-23153-001-B-0513 |
524 KB PDF |
| REPAIR PARTS - BCUZ SERIES 13 SEER SINGLE PACKAGED HEAT PUMPS (STYLE A) |
035-23461-001-A-0313 |
468 KB PDF |
| User Manuals |
| BUZ, BUX, BUQ024 thru 060 Single Package Heat Pumps with R-410A Refrigerant (13 SEER) |
103643-BUM-B-0106 |
127 KB PDF |
|
|
|